Basic, stand alone safety applications require safety relays that are flexible, easy to troubleshoot and simple to install.  The SR1 faimly of safety monitoring relays address all of those needs.  With dedicated safety functions and expansion capabilities, the SR 1 supports the flexibility you need.  Easy to access diagnostic indicators make troubleshooting quick and stress-free while the fixed terminals make installation of the SR1 simple.  The SR1 makes all of machine safety projects easier and provides the protection you need.

+1 (800) 556-6766Datasheet
Tabs
  • Power requirements — accepts 24 VAC/DC or 115 VAC
  • Inputs — single N/C input channel, not monitored is provided
  • Outputs — has two N/O outputs to route power to the coils of power contactors

Overview

Conforms to EN60439-1, EN60947-1/5/7, EN61000-6, EN62061, EN ISO 13849-1, UL and C-UL listed, TÜV Rheinland approved

  • External Device Monitoring (EDM) is provided with a N/C loop between S11 and S21 on the SR101A
  • Reset mode — an automatic reset mode is provided with the SR101A

Dual-Channel Safety Monitoring Relay

Fixed terminal relay with (2) 1 N/C + 1 N/O inputs

  • Power requirements — accepts 24 VDC
  • Inputs — monitors two magnetically encoded non-contact switches with 1 N/C and 1 N/O contacts
  • Outputs — has 2 N/O outputs to route power to the coils of external device power contactors plus 2 N/C auxiliary solid state outputs for signaling purposes

Conforms to EN60947-1/5, EN61000-6, EN62061, EN ISO 12100-2, EN ISO 13849-1/2, EN ISO 13850, UL and C-UL listed, CSA and TÜV Rheinland approved

  • External Device Monitoring (EDM) is provided with a N/C loop between Y1 and Y2
  • Selectable reset modes — automatic/manual reset mode

Stop Motion Sensing Unit

Fixed terminal relay with back EMF inputs

  • Power requirements — accepts 24 VDC or 110 VAC
  • Motion detection input — detects the stop condition of all types of AC or DC motors by sensing the motor’s back EMF across terminals Z1, Z2 and Z3
  • Drive compatible — functions with electronic motor control devices such as variable speed controllers, DC injection brakes, etc.

Conforms to EN60947-1/5, EN61000-6, EN62061, EN ISO 12100-2, EN ISO 13849-1/2, EN ISO 13850, UL and C-UL listed, CSA and TÜV Rheinland approved

  • Selectable speed limit — 1 N/O and 1 N/C outputs that are switched when motor speed reaches the adjustable preset limit (0.01 to 0.10 V) for the particular output
  • Auxiliary output — 2 solid state auxiliary signaling outputs

Dual-Channel Safety Monitoring Relay

Fixed terminal relay with 1 N/C, 2 N/C, PNP Inputs and safety OFF delay timer outputs.

  • Power requirements — accepts 24 VAC/DC
  • Inputs — accepts single or dual N/C inputs or dual PNP solid-state inputs from a light curtain
  • Outputs — have a total of 2 N/O + 2 N/O (time delay) + 1 N/C Aux. (time delay) outputs with 3, 2 or 1 of the outputs with a time delay of 1-30 sec.

Conforms to EN60439-1, EN60947-1/5/7, EN61000-6, EN62061, EN ISO 13849-1, UL and C-UL listed, TÜV Rheinland approved

  • External Device Monitoring (EDM) is provided with a N/C loop between S12 and S21
  • Reset mode — a monitored manual start or an auto/manual start. Monitored manual reset requires closure of the reset circuit followed by opening of the circuit. Reset occurs when circuit is opened. Auto reset requires only closure of the reset circuit as reset occurs when circuit is closed.
  • PLC Compatible — The N/O off delayed outputs make it possible to use on machines with Programmable Logic Controllers that require some time to execute an orderly shutdown

Dual-Channel Safety Monitoring Relay

Fixed terminal relay with 1 N/C, 2 N/C, PNP Inputs and safety OFF delay timer outputs

  • Power requirements — accepts 24 VAC/DC
  • Inputs — accepts single or dual N/C inputs or dual PNP solid-state inputs from a light curtain
  • Outputs — have a total of 2 N/O + 3 N/O (time delay) outputs with 3, 2 or 1 of the outputs with a time delay of 1-30 sec.

Conforms to EN60439-1, EN60947-1/5/7, EN61000-6, EN62061, EN ISO 13849-1, UL and C-UL listed, TÜV Rheinland approved

  • External Device Monitoring (EDM) is provided with a N/C loop between S12 and S21
  • Reset mode — a monitored manual start or an auto/manual start. Monitored manual reset requires closure of the reset circuit followed by opening of the circuit. Reset occurs when circuit is opened. Auto reset requires only closure of the reset circuit as reset occurs when circuit is closed.
  • PLC Compatible — The N/O off delayed outputs make it possible to use on machines with Programmable Logic Controllers that require some time to execute an orderly shutdown

Two-Hand Control Safety Monitoring Relay

Fixed terminal relay for two-hand palm buttons

  • Power requirements — accepts 24 VAC/DC and 115 VAC
  • Inputs — controls and monitors two-hand control switches to ensure that both switches are operated within 0.5 seconds of each other
  • Outputs — has 2 N/O outputs to route power to the coils of power contactors

Conforms to EN62061, EN60947-5-1, EN ISO 13849-1, EN ISO 13849-2, EN574, UL and C-UL listed, TÜV Rheinland approved

  • External Device Monitoring (EDM) is provided with a N/C loop between X1 and X2 on the SR104P

Dual-Channel Safety Monitoring Relay

Fixed terminal relay with 1 N/C, 2 N/C, and PNP Inputs

  • Power requirements — accepts 24 VAC/DC or 115 VAC
  • Inputs — accepts single or dual N/C inputs or dual inputs from a light curtain
  • Outputs — has 3 N/O outputs to route power to the coils of power contactors, plus 1 N/C auxiliary output for signaling purposes

Conforms to EN60439-1, EN60947-1/5/7, EN61000-6, EN62061, EN ISO 13849-1, UL and C-UL listed, TÜV Rheinland approved

  • External Device Monitoring (EDM) is provided with a N/C loop between S11/S12 and S21 on the SR103AM
  • Monitored manual or automatic/manual reset modes are available on the SR103AM.  Monitored manual reset requires closure of the reset circuit followed by opening of the circuit. Reset occurs when circuit is opened. Auto reset requires only closure of the reset circuit as reset occurs when circuit is closed.