Target Products

  • Machine Automation Controllers SYSMAC-SE200D SYSMAC-SE200D-64
  • There is no modification in SYSMAC-SE2□□L, SYSMAC-VE0□□L, SYSMAC-ME0□□L, SYSMAC-NE0□□L, SYSMAC-DE0□□L, SYSMAC-FE0□□L, SYSMAC-TA4□□L, or SYSMAC-SA4□□L-64 because they are license certificates.
  • Refer to the " Details of applicable model"

SYSMAC-SE200D (32bit)

  • Effective as of our production on January 9, 2024

SYSMAC-SE200D-64 (64bit)

  • Effective as of our production on January 9, 2024

Reasons for change

  • To improve the quality of Sysmac products.

Support the following Controllers

  • NXR-ILM08C-ECT

V.1.57 New Functions 

Controller

Support export and import of axis settings and axes group settings.

**Explains the detail on the later page.

Support deleting multiple axis settings and axes group settings.

**Explains the detail on the later page.

It is now possible to edit sampling settings of Automation Playback while the Controller is in operation.

**Explains the detail on the later page.

It is now possible to select collection targets for Automation Playback in units of variables.

**Explains the detail on the later page.

Controller Details

  • Solved the problem that structure members were sometimes not copied even when the structure was copied while conducting the Detailed Comparison in the Version Control function.
  • Solved the problem that inconsistencies in project data could occur when overwriting data types with overlapping namespaces while conducting the Detailed Comparison in the Version Control function.
  • Solved the problem that the Detailed Comparison window for the Version Control function might indicate “Different” in Comparison Results even after erasing all differences.
  • Solved the problem that when opening the Detailed Comparison window of the Version Control function, the re-comparison window sometimes opened many times.
  • Solved the problem that some variables were sometimes not found on the rung pattern copy setting window.
  • Solved the problem that numbers were not automatically added to the end of the project name when importing multiple of the same project.
  • Solved the problem that the topology associated with the EtherCAT port could not be restored when importing an IEC 62714 AutomationML file.

HMI

  • Solved the problem that unnecessary property items were sometimes displayed when editing an object within an IAG after running a simulation.
  • Solved the problem that changing a controller name after performing Save As might not be reflected in the HMI.
  • Runtime:Solved the problem that a character string of an IAG object was displayed in an unintentional manner when there were objects with the same name for a Tab Control and an IAG.

Robot Integrated CPU Unit

  • Solved the problem where the behavior area could not be snapped to a specific 3D object while setting behaviors.

Details of Applicable Models

  • SYSMAC-SE200D
  • SYSMAC-SE200D-64