Target Products
- Machine Automation Controllers SYSMAC-SE200D SYSMAC-SE200D-64
- There is no modification in SYSMAC-SE2□□L, SYSMAC-VE0□□L, SYSMAC-ME0□□L, SYSMAC-NE0□□L, SYSMAC-DE0□□L, SYSMAC-FE0□□L, SYSMAC-TA4□□L, or SYSMAC-SA4□□L-64 because they are license certificates.
- Refer to the " Details of applicable model"
SYSMAC-SE200D (32bit)
- Effective as of our production on May 16, 2024
SYSMAC-SE200D-64 (64bit)
- Effective as of our production on May 16, 2024
Reasons for change
- To upgrade Sysmac products.
Changes
Please refer to “20231205_PDC_00002 : Modification Notice of Automation Software Sysmac Studio (SYSMAC-SE200D and SYSMAC-SE200D-64)” about the change of System Requirements: Operating system.
Support the following Controllers
- NXR-ILM08C-ECT
V.1.58 New Functions
The functions below were not provided in Ver.1.57 or older.
Support the following Controller
- NX502 CPU Unit ver. 1.66
- NX502-1600
- NX502-1700
Support the following X Bus Unit
- NX-EIP201 Ver. 1.01
New Safety Functions
- NX-EIP201 Unit allows both communication methods, CIP Safety and Tag Data Link, simultaneously.
- It is possible to print a FBD program at a high resolution.
- It is possible to select the printing magnification for FBD programs.
Improved Common Sysmac Studio Functions
- Solved the problem that canceling an NA integrated simulation during preparation and re-trying the simulation could force-quit Sysmac Studio.
- Solved the problem that switching devices or using features provided by option licenses might force-quit Sysmac Studio.
Improved Controller Functions
- Solved the problem that editing a program, running a simulation, or performing online editing repeatedly might display the message saying "Unexpected changes were detected" and disable online editing.
- Solved the problem that detailed comparison was not available for data types while opening Sysmac Diff from the Show Change History for Project menu in Version Control.
- Solved the problem that explanations for initialization parameter setting items on the EtherCAT slave parameter setting window might not be displayed correctly.
- Revised the message displayed by clicking Reset All on the troubleshooting dialog for Controller.
- Solved the problem that even when the initial value of a variable was not correct, the variable table might not indicate an error.
- Solved the problem that opening the File menu might shut down Sysmac Studio abnormally.
- Solved the problem that specifying a long folder path to export a project file might shut down Sysmac Studio abnormally.
- Solved the problem that a comparison result might not be displayed correctly when drag and drop a section of a ladder program to another ladder program.
- Solved the problem that using the same variable in many locations in a ladder rung diminished the performance of the Ladder Editor.
- Improved the performance when changing the controller model.
Improved Safety Functions
- Solved the problem that displaying controller status of a Safety CPU Unit might force-quit Sysmac Studio.
- Solved the problem that monitoring a Safety I/O Unit might force-quit Sysmac Studio.
- The file exported by the coupler unit I/O mapping export function includes an SRA parameter list.
Improved HMI Function
- Solved the Version Control problem that an IAG with conditions incapable of merging was merged.
- Solved the problem that copying an image file once registered as a resource after it had been removed might shut down Sysmac Studio abnormally.
- Corrected a wrong Chinese description about serial port parity settings.
- Solved the problem that IAG events were not displayed.
Runtime Solutions
- Solved the problem that setting an out-of-range value to the max. or min. value of a broken-line graph in Soft-NA abended Sysmac Studio.
- Solved the problem that an attempt to display a page with quite a lot of reference variables might abend Soft-NA or the simulator.
- Solved the problem that an error might not be indicated properly or Soft-NA or the simulator might abend when the page display went into an infinite loop.
- Solved the problem that the troubleshooter might cause an error while attempting to display the event log of an NX Unit on the EtherCAT Coupler Unit.
- Solved the problem that the Safety Monitor might cause an error while connecting to a Safety CPU Unit on the EtherCAT Coupler Unit.
- Solved the Version Control problem that an IAG with conditions incapable of merging was merged.
- Solved the problem that copying an image file once registered as a resource after it had been removed might shut down Sysmac Studio abnormally.
- Corrected a wrong Chinese description about serial port parity settings.
- Solved the problem that IAG events were not displayed.
- Solved the problem that setting an out-of-range value to the max. or min. value of a broken-line graph in Soft-NA abended Sysmac Studio.
- Solved the problem that an attempt to display a page with quite a lot of reference variables might abend Soft-NA or the simulator.
- Solved the problem that an error might not be indicated properly or Soft-NA or the simulator might abend when the page display went into an infinite loop.
- Solved the problem that the troubleshooter might cause an error while attempting to display the event log of an NX Unit on the EtherCAT Coupler Unit.
- Solved the problem that the Safety Monitor might cause an error while connecting to a Safety CPU Unit on the EtherCAT Coupler Unit.
Improved Robot Integrated CPU Unit
- Solved the problem where mechanical components and parallel link models imported through the 3D object import functionality could not be version-controlled.
- Solved the problem where the collision detection for mechanical components was not working properly during a behavior simulation.
Details of Applicable Models
- SYSMAC-SE200D
- SYSMAC-SE200D-64