Support the following Controllers:

Support the following NX unit (EtherCAT slave unit):

  • NX-ECT101 Ver.1.0

Support the following Controllers:

  • NJ101-1[]00 Controller Ver.1.49
  • NJ101-1[]20 Controller Ver.1.49
  • NJ301-1[]00 Controller Ver.1.49
  • NJ501-1[]00 Controller Ver.1.49
  • NJ501-1[]20 Controller Ver.1.49
  • NJ501-1340 Controller Ver.1.49
  • NJ501-40 Controller Ver.1.49
  • NJ501-5300 Controller Ver.1.49
  • NJ501-R0 Controller Ver.1.49
  • NX102 Controller Ver.1.49
  • NX1P2 Controller Ver.1.49
  • NX701Controller Ver.1.29

Support the following OMRON robots connectable to NJ501-R0 Controllers:

  • EtherCAT (NJ501-R) compliant version of i4-350L, 450L, and 550L

New Functions

Users can reuse the controller configuration and variables (symbol names) of IO terminals created in EPLAN Electric 8, an electric CAD software, in Sysmac Studio.

New functions are available to enhance NJ/NX Controllers’ security.

  • User authentication
  • TCP/UDP port closing
  • Packet filter
  • Secure communication
  • Added the event settings exporting function for SYSMAC Gateway’s Event Log Utility

Improved Functions

Controller

  • Solved the problem that when a variable was shared in devices, selecting Comment 2 from the Select comment drop-down was not reflected in the shared variable's comment correctly.
  • Solved the problem that Sysmac Studio mis-detected a large-size project overwritten by the Version Control function as data edited from outside.
  • Solved the problem that cross referencing was inoperable during online editing.
  • Solved the problem that using a function or function block containing the range-specified data type in input/output/in-out variables in an ST program caused a build error.
  • Solved the problem that (To Lower Layer) might not be enabled in a user-defined function where a name space was set.
  • Solved the problem that an in-out variable for a function or function block could not be moved to the internal variable group.
  • Solved the problem that the IEC61131-10 XML Import function might not import an XML file when a comma (,) was used as a decimal point in the Windows Location settings.
  • Solved the problem that a device variable assigned to a node port in the I/O Map could be moved from a variable table to another one.
  • Solved the problem that if more than one library had a POU with the same name, and the option whether includes the POU or not was configured differently, the POU might be unavailable.

Safety

  • Solved the problem that uploading (Transfer from Controller) a Safety CPU Unit program that contains the 1S series Servo Drive might terminate Sysmac Studio abnormally.
  • Solved the problem that Sysmac Studio might end while editing a program on the FBD editor.
  • Solved the problem that after sorting exposed variables in the global variable table, sorting a column in different variable table might terminate Sysmac Studio abnormally.

HMI

  • Solved the problem that a direct copy-and-paste the CX-Programmer variables to the device variable table was not available.
  • (Runtime) Support the secure communications with NJ/NX series CPU Units.
  • Viewer might not be out of position from those of the displayed recipe.

Robot Integrated CPU Unit

  • Shape Script Default Functions can be updated to the highest version that Sysmac Studio has.
  • Solved the problem that a wrong error message might appear at a mis-configuration of Robot Vision Manager in Application Manager.
  • Solved the problem that a V+ variable value might return after an upload of a project from a Robot Integrated CPU Unit.
  • Solved the problem that the Synchronisation window of RobotControlSettings might hide behind the main window.
  • Solved the problem that pressing the Here button on the V+ Jog Control pane might not register a variable to location variables.
  • Solved the problem that a message saying "Robot not attached to this program" might appear for a program with a robot registered.
  • Corrected the Viper CAD data.
  • Solved the problem that importing a project file caused a controller mismatch on the Synchronisation window in Application Manager.
  • Solved the problem that the Syncronisation window did not show a mismatch after editing a specific property of AnyFeeder.
  • Solved the problem that a comma-separated numeric value entered in the mechanical component setup tab page was set without the comma.
  • Corrected the wrong orientation of i4H's tool flange in the 3D simulator.
  • Solved the problem that Sysmac Studio might abend while uploading an Application Manager.
  • Solved the problem that an error appeared when adding an OMRON Sentech camera.