Support of New Type

Supported the following NX-series Temperature Control Unit (NX-TC)

  • NX-TC240[] Ver.1.2
  • NX-TC340[] Ver.1.2

Supported the following Vision Sensors.

  • FH-series Ver.6.3
  • FHV-series Ver.6.3

New functions

  • Supported the import function of IEC61131-10XML.
  • Supported the import function of IEC61131-10XML.

Improved functions

  • Solved the problem that an error might occur when importing comments of structure type variables that include “_”.
  • Solved the problem that project transfer might fail if the model was changed from NX1P2 Controller to NX102 Controller in the project.
  • Solved the problem that some version-controlled projects could not be saved after they referenced library files.
  • Solved the problem that some version-controlled library projects could not be saved if libraries were created in those projects.
  • Solved the problem that some version-controlled library projects could not be reopened after you created libraries on those projects and closed the projects without saving them.
  • Solved the problem that library reference setting was discarded if referenced library files did not exist when you created a library in the library project.
  • Solved the problem that data type before editing might be transferred when a project was synchronized, and then downloaded to the Controller after editing a data type.
  • Solved the problem that Sysmac Studio became inoperable if you edited a variable comment of a Controller in a project that included a Controller and a Safety device, and then connected the project online to the Controller.
  • Solved the problem that Sysmac Studio terminated forcibly, if you edited the variable table while instance names in the function block were not determined.
  • Solved the problem that I/O allocation order might change if the model number of the Safety I/O Unit was changed while its FSoE communications is disabled.
  • Solved the problem that the InteliSense might not work on the code editor.
  • Solved the problem that Sysmac Studio might terminate abnormally when the Runtime version was changed to V1.11.
  • Solved the problem that source code might not be uploaded normally.
  • Solved the problem that when multiple languages were used on an HMI with runtime version 1.11 or later, a font of non-default language of the user-defined alarm object was displayed as the default font.
  • Solved the problem that Sysmac Studio might terminate abnormally while it is connected online with an HMI.
  • Solved the problem that an error might occur when a project that included a Controller and an HMI was saved after uploading from the HMI.
  • Solved the problem that Controller’s system-defined variables were automatically registered as variables of an HMI, if the project was uploaded while variable mapping setting is set to “Auto”.

Solved the following problems in simulation of NJ5/1-series Controllers.

  • In relative positioning, there were configurations which caused “Travel Distance Out of Range”.
  • In a program where MC_SetPosition was used multiple times, Velocity actual value might be larger than the actual velocity.
  • A “Motion Control Parameter Setting Error” might occur.